• Description
  • Dimensions
  • Owners Manual
  • Data Sheet

mid chiller aisle image mid c195 cambridge chiller cabinetCambridge Chiller

This narrow footprint case has a footprint of only 677mm deep, ensuring economical use of the compact sales floors found in convenience stores of petrol station forecourts.

With the introduction of LED lights and low energy fan motors, helping these cases achieve very low energy consumption figures.

Available with Hydrocarbon refrigerants, ensures these cases are future proof in regards to global warming legislation.

cambridge line drawing

Cambridge R407f Range Data Sheet

C096
Electrical Data Watt Supply 1
(amp)
Condensing units 897 3.9
Defrost heater - -
Doors & Frames - -
Evaporator fans 62.1 0.27
Light (LED) 9.2 0.04
Load Refrigeration 968.3 4.21
Load Defrost 71.3 0.31
Energy Consumption (Kwh/24hrs) 19.1 -
Refigeration Data  
Systems 1
Refrigerant R407f
Controller Dixell XW82K
Defrost frequency 4hr
Defrost termination 8C
Set point 2C
Defferential 4C

spacer

C110
Electrical Data Watt Supply 1
(amp)
Condensing units 966 4.2
Defrost heater - -
Doors & Frames - -
Evaporator fans 52.9 0.23
Lights (LED) 9.2 0.04
Load Refrigeration 1028.1 4.47
Load Defrost 62.1 0.27
Energy Consumption (Kwh/24hrs) 20.5 -
Refigeration Data  
Systems 1
Refrigerant R407f
Controller Dixell XW82K
Defrost frequency 4hr
Defrost termination 8C
Set point 2C
Defferential 4C

spacer

C130
Electrical Data Watt Supply 1
(amp)
Condensing units 959.1 4.17
     
     
Evaporator fans 59.8 0.26
Light (LED) 11.5 0.05
Load Refrigeration 1030.4 4.48
Load Defrost 71.3 0.31
Energy Consumption (Kwh/24hrs) 20 -
Refigeration Data  
Systems 1
Refrigerant R407f
Controller Dixell XW82K
Defrost frequency 4hr
Defrost termination 8C
Set point 2C
Defferential 4C

spacer

C150
Electrical Data Watt Supply 1
(amp)
Condensing units 1173 5.1
     
     
Evaporator fans 62.1 0.27
Lights (LED) 9.2 0.04
Load Refrigeration 1244.3 5.41
Load Defrost 71.3 0.31
Energy Consumption (Kwh/24hrs) 28.9 -
Refigeration Data  
Systems 1
Refrigerant R407f
Controller Dixell XW82K
Defrost frequency 4hr
Defrost termination 8C
Set point 2C
Defferential 4C

spacer

C195
Electrical Data Watt Supply 1
(amp)
Condensing units 1888.3 8.21
     
     
Evaporator fans 66.7 0.29
Lights (LED) 16.1 0.07
Load Refrigeration 1971.1 8.57
Load Defrost 82.8 0.36
Energy Consumption (Kwh/24hrs) 34.7 -
Refigeration Data  
Systems 2
Refrigerant R407f
Controller Dixell XW82K
Defrost frequency 4hr
Defrost termination 8C
Set point 2C
Defferential 4C

spacer

C230
Electrical Data Watt Supply 1
(amp)
Condensing units 2067.7 8.99
     
     
Evaporator fans 82.8 0.36
Lights (LED) 20.7 0.09
Load Refrigeration 2171.2 9.44
Load Defrost 103.5 0.45
Energy Consumption (Kwh/24hrs) 37.5 -
Refigeration Data  
Systems 2
Refrigerant R407f
Controller Dixell XW82K
Defrost frequency 4hr
Defrost termination 8C
Set point 2C
Defferential 4C

spacer

C250
Electrical Data Watt Supply 1
(amp)
Condensing units 2056.2 8.94
     
     
Evaporator fans 94.3 0.41
Lights (LED) 18.4 0.08
Load Refrigeration 2168.9 9.43
Load Defrost 112.7 0.49
Energy Consumption (Kwh/24hrs) 42 -
Refigeration Data  
Systems 2
Refrigerant R407f
Controller Dixell XW82K
Defrost frequency 4hr
Defrost termination 8C
Set point 2C
Defferential 4C

Pin It

Verco Limited
Hithercroft Road
Wallingford
Oxfordshire
OX10 9DG

Company Reg.: 1829633


Telephone: +44 (0) 1491 839966
Fax: +44 (0) 1491 835656

iso 9001 mark 75

Connect With Us